The facades of this high-rise office building consist of precast concrete walls finished with marble panels. Several marble panels exhibited extensive cracking and out-of-plane warping. FKC performed a condition survey and retrieved marble samples for laboratory testing. FKC investigated the effects of the various design and construction details including the marble anchoring system. A report was issued with findings, conclusions and recommendations.

   